What was found
THIS EO IS BEING ISSUED TO PROVIDE INSTRUCTIONS TO ACCOMPLISH THE PERMANENT REPAIR OF THE FWD SERVICE DOOR GUSSET PLATE, PN 170-69277-003, CHAFE DAMAGE BY FABRICATION & REPLACEMENT. THE CHAFE DAMAGE MEASURES APPROX THE FOLLOWING DIMENSIONS, 2.0 INCHES X 2.0 INCHES X .016 INCH DEEP. REQUESTED RELIEF & RESPONDED TO REPLACE THE PART. THE GUSSET PLATE IS TO BE FABRICATED & REPLACED IAW PRODUCTION DWGS & SRM. NO FOLLOW UP INSPECTIONS ARE REQUIRED DUE TO FABRICATION & DIRECT REPLACEMENT OF THE PART IAW PRODUCTION DWGS. ENGINEERING HAS CLASSIFIED THIS AS A MAJOR REPAIR. ACCOMPLISHMENT OF THIS MAJOR REPAIR IS ON EO E175-52MR-005 UNDER WO 2049218.