What was found
DURING BASIC CHECK AT EAMS, TWO SMALL GOUGE DAMAGES O/B OF RIB 3 ON THE LH HORIZONTAL STABILIZER UPPER SKIN (P/N 170-62726-015). REFERENCE ETD2020-170-000754, FIGURE 1 FOR DETAILS, FOR THE DAMAGE LOCATION AND DIMENSION. EAMS REQUESTED & RECEIVED PERMANENT REPAIR DISPOSITION IN THE FORM OF ETD2020-170-000754, WHICH ALLOW THE AREAS TO BE BLENDED AND LEAVE AS-IS, PROVIDED NDT INSPECTION VERIFIES DAMAGE REMOVAL AND SURFACE PROTECTION IS RESTORED. COMPASS ENGINEERING HAS CLASSIFIED THIS AS A MINOR REPAIR. WORK ORDER 273581628