What was found
SLAT FAIL ON FINAL APPROACH. CLEARED SLAT FAIL MESSAGE IAW FIM TASK 27-81-00-810-803A. OPS TEST OF FLAP AND SLAT, GOOD, ACFT OK FOR SERVICE. IAW COMPANY REQUEST R & R LT SLAT, 3/4 HARNESS PN 171-10231-401, SN FO33911661, LT HARNESS SLAT 2/3 PN 171-00187-401, SN FO35341193 AND LT OTBD SLAT SKEW SENSOR 1702286B SN 2765. ALL OPS CHECKED GOOD IAW AMM 27-83-01 AND 27-83-07. ACFT OK FOR SERVICE.