What was found
WHILE IN HEAVY MAINTENANCE PERFORMING INSPECTIONS IT WAS NOTED THAT SHEAR TIE LOCATED AT STATION 580 STRINGER 26R-27R WAS CORRODED. REMOVED DAMAGED SHEAR TIE. FABRICATED NEW SHEAR TIE FROM 7075-O .071 INCH (8 INCHES X 2 INCHES) HEAT TREATED TO T6. INSTALLED NEW SHEAR TIE IAW 51-40-2, 53-10-2. NO OTHER DEFECTS NOTED. ACFT WAS RETURNED TO SERVICE.