As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING CLIMB OPERATION, THE OTBD FLAPS FROZE AT 3 DEGREES ON CLIMBOUT, 9 UNITS OF AILERON TRIM WAS REQUIRED FOR LEVEL FLIGHT. THE ACFT RETURNED TO DEPARTURE WHERE IT LANDED WITHOUT INCIDENT. POST FLIGHT INSP WAS PERFORMED NOTING THAT BOTH RT OTBD FORE FLAP SEQUENCING HAVE NUMEROUS BROKEN BOLTS. R & R BOTH SEQUENCING CARRIAGES AND PERFORMED OPS CHECK. NO DEFECTS WERE NOTED AND THE ACFT WAS RETURNED TO SERVICE.