Service difficulty report · Cable Guard · Cndair CL2156B11415

Difficulty date
November 28, 2000
Submitted
January 19, 2001
Operation
Air carrier
Make and model
Cndair CL2156B11415
Aircraft time
698 hours
Part
Cable Guard
Condition
Worn
Location
Cockpit
Part time
792 hours
Component
Cable Guard
Stage of operation
IN
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) DURING AN ANNUAL INSPECTION, WE HAVEFOUND A CABLE GUARD THAT WAS RUBBING ON THE AILERON MULTIPLIER REAR CABLE WHICH COMES FROM THE PILOTS SIDE CABLE. WE THEN CHECKED A/C 2017 AND FOUND THE SAME PROBLEM. WE WILL CARRY OUT AN INSPECTION OF ALL CL415.AT THIS TIME THE DISMANTLING OF THE MULTIPLIER HAS BEEN CARRIED OUT ON A/C 2017 AND THE GUARD HAS BEEN FOUND WORN BY APPROXIMATELY .030. HOWEVER, THE CABLE DID NOT SHOW ANY SIGN OF DAMAGE. SEE ATTACHED PICTURES.