Service difficulty report · Contactor · Dhav DHC8*

Difficulty date
November 4, 2001
Submitted
December 12, 2001
Operation
Air carrier
Make and model
Dhav DHC8*
Engine
Pwa PW123
Propeller
Hamstd 14SF23
Part
Contactor
Part number
82450026
Condition
Burned
Location
Electrical
Stage of operation
CR
How discovered
O
Nature of condition
H
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) SPU AUXILIARY POWER LIGHT WAS FLICKERING IN FLIGHT. INVESTIGATION CARRIED OUT AND THREE 12 AWG WIRES FOUND CHAFED / BURNT INSIDE THE NR 2 AC CONTACTOR BOX. THE WIRE IDENTS ARE AS FOLLOWS:20005B12C-1, 20003B12B-1 AND 20001B12A-1. THESE WIRES GO BETWEEN CIRCUIT BREAKERS CB8 AND CB6 IN THE RT AC CONTACTOR BOX. THE CHAFF WAS FROM A BOLT ATTACHING A TERMINAL BLOCK TO THE BACK OF THE CONTACTOR BOX. REPAIR CARRIED OUT.