Service difficulty report · Wire · Bombdr BD7001A10

Difficulty date
October 10, 2002
Submitted
October 28, 2002
Operation
Air carrier
Make and model
Bombdr BD7001A10
Engine
Rroyce BR700710A220
Part
Wire
Part number
GT41559009
Condition
Pinched
Location
Sfcu
Component
Sfcu · GT41559009
Stage of operation
NR
How discovered
O
Nature of condition
J
Precautionary procedure
H

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) DURING RETURN TO SERVICE TESTING AFTER A MAINTENANCE DOWNTIME, THE FLAPS WERE OPERATED AND WHEN THEY REACHED APPROXIMATELY 30 DEGREES, AN AVIONICS SMOKE MESSAGE WAS OBSERVED. PRIOR TO POWER BEING REMOVED FROM THE A/C, A SLAT/FLAP HALF SPEED MESSAGE WAS ALSO POSTED. SUBSEQUENTLY IT WAS DISCOVERED THAT THE CIRCUIT BREAKER G9 (SFCU) HAD TRIPPED. TROUBLESHOOTING THE MESSAGES LED THE TECHNICIAN TO INSPECT THE SFCU IN THE AVIONICS BAY. THE INSULATION BLANKET AROUND THE SFCU WAS FOUND TO BE HEAT DAMAGED AND SOME SOOT WAS FOUND AT THE SFCU COOLING VENTS AS WELL ON THE SURROUNDING STRUCTURE & DUCTING. PRELIMINARY REPORTS INDICATE AN INTERNAL PINCHING OF A WIRE IN THE CURRENT SENSOR CIRCUIT.