Service difficulty report · Generator · Cndair CL2151A10

Difficulty date
April 13, 2003
Submitted
June 16, 2003
Operation
General aviation
Make and model
Cndair CL2151A10
Part
Generator
Part number
2CM70D6A
Part serial
755322
Condition
Failed
Location
Electrical
Stage of operation
NR
How discovered
9
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) TWO GENERATORS HAD 8130 FORMS STATING THAT GENERATORS HAD BEEN OVERHAULED AND TESTED. AFTER A GROUND GENERATOR FIRE DURING INITIAL RUNUP ON THE FIRST UNIT, THE SECOND GENERATOR THAT HAD BEEN INSTALLED ON ANOTHER AIRCRAFT BUT NOT RUN YET WAS REMOVED FOR INVESTIGATION. COMPANY OVERHAUL SHOP INSPECTED THE INTERNAL PARTS OF THE REMAINING GENERATOR AND FOUND EVERYTHING CLEAN EXCEPT THAT THE BRUSHES WERE BRAND NEW AND HAD NOT BEEN RUN IN AT ALL. UPON 5 MINUTES OF TESTING WITH A CURRENT ON TO WEARING THE BRUSHES, THE GENERATOR STARTED MAKING STRANGE NOISES AND BEGAN SMOKING. TEST WAS HALTED. GENERATORS SENT BACK TO SUPPLIER FOR INVESTIGATION AND CREDIT.