What was found
(CAN) COMPLETED CF-91-42, SB 2/47 REV.C ON POST MOD 2/758 STABILIZER. NO CRACK WAS INITIALLY DETECTED. ALTHOUGH IT IS NOT REQUIRED BY THE AD, BRACKETS C2TP159A AND C2TP160A WERE REMOVED FOR DETAILED VISUAL INSPECTION OF THE SPAR. THE SPAR WAS FOUND CRACKED UNDER THE RT BRACKET (C2TP160A) APPROXIMATELY .2500 INCHES ABOVE THE TOP BRACKET BOLT HOLE. THE GUSSET PLATE C2TP171 WAS ALSO CRACKED DIRECTLY BEHIND THE SPAR CRACK. THESE CRACKS ARE LOCATED PARALLEL TO AND DIRECTLY IN FRONT OF THE RADIUS OF WASHER PLATE P/N C2TP177. BOTH CRACKS ARE APPROXIMATELY .2500 - .6258 INCHES LONG.