What was found
(CAN) HYDRAULIC SELECTED OFF. HYDRAULICS TOOK 35 SECONDS TO TURN OFF. SUSPECT SLIDER STICKING OPEN. REPLACED HYDRAULIC CONTROLLER (REGULATOR) WITH SERVICEABLE UNIT. TEST NORMAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
(CAN) HYDRAULIC SELECTED OFF. HYDRAULICS TOOK 35 SECONDS TO TURN OFF. SUSPECT SLIDER STICKING OPEN. REPLACED HYDRAULIC CONTROLLER (REGULATOR) WITH SERVICEABLE UNIT. TEST NORMAL.