Service difficulty report · Relay · Cndair CL6002C10

Difficulty date
November 15, 2003
Submitted
January 5, 2004
Operation
General aviation
Make and model
Cndair CL6002C10
Engine
Ge CF348C1
Part
Relay
Condition
Failed
Location
Generator
Stage of operation
CR
How discovered
O
Nature of condition
F
Precautionary procedure
H

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) FLAPS FAIL, CAUTION MESSAGE POSTED AND SLATS FAIL, CAUTION MSG POSTED ON ADG (AIR DRIVEN GENERATOR) POWER, UNABLE TO MOVE FLAPS. AFTER POWER WAS RESTORED, SLATS HALFSPEED AND FLAPS HALFSPEED STATUS MSG WERE POSTED AND DISAPPEARED AFTER LANDING. RELAY HAS BEEN CYCLED AND RETESTED IAW OUR FLIGHT TEST PROCEDURE NR S670-242301 PARA. 8.1.6 AND 8.1.7. SLATS AND FLAPS FOUND SERVICEABLE IAW FTP S670-275001. SUBSEQUENT FLIGHT TESTING BEING SUCCESSFUL. CURRENTLY, ENGINEERING IS UNDER INVESTIGATION FOR A SIMILAR ISSUE WITH ANOTHER AC 10118 WHERE NO ACCESS BUS POWER WAS AVAILABLE ON ADG POWER DURING A FLIGHT TEST AND AFTER POWER RESTORATION, EVERYTHING CAME BACK NORMAL. THE SECOND ATTEMPT ON ADG WAS SUCCESSFUL.