As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ON APPROACH WITH FLAPS SELECTED TO 15 DEG STALL IDENT LIGHT CAME ON THE ANNUNCIATOR PANEL. ON INVESTIGATION FOUND FLAP OUTBD MICROSWITCH OFF THE CAM FROM SWITCH ASSY. FURTHER INVESTIGATION WAS CARRIED OUT AND FOUND THE OUTBD BRACKET BROKEN FOR SWT SUPPORT. REPLACED OUTBD BRACKET P/N 140-700013-0001 WITH NEW UNIT. C/O RIGGING AND FUNCTIONALS AS PER RAYTHEON MM CH.27-33-23-501. C/O FUNCTIONALS ON STALL IDENT SERVICEABLE.