What was found
(CAN) DURING A 50 HOUR ROUTINE INSPECTION MAINTENANCE PERSONEL DISCOVERED THAT THE AILERON TRIM WAS NOT MOVING. UPON INSPECTION OF THE SYSTEM IT WAS DISCOVERED THAT THE AILERON TRIM ACTUATOR WAS SEIZED. THE ACTUATOR WAS REMOVED AND DISSASSEMBLED. THERE WAS INTERNAL RUST IN THE TRIM ACTUATOR HOUSING AND ONE BEARING WAS SEIZED. (TC NR 20071010008)