What was found
(CAN) ON APPROACH LANDING GEAR LEVER SELECTED DOWN. EICAS MESSAGE " BRK CTRL FAULT" FOLLOWED BY LT MLG SHOWED RED AND NOT DOWN AND LOCKED. GEAR RECYCLED SAME RESULT HOWEVER AFTER A FEW SECONDS EICAS MESSAGE WENT OUT AND GOT 3 GREEN GEAR DOWN LIGHTS. LANDING GEAR SYS INSPECTED, LUBE, BLEED AIR FROM UPLOCK ACTUATOR. LANDING GEAR EXTENSION AND RETRACTION SYS TEST, EMERGENCY EXTENSION SYS TEST CARRIED OUT AS IAW SNL 190-32-0025.