Service difficulty report · Blower · Beech 1900D

Difficulty date
February 2, 2010
Submitted
March 1, 2010
Operation
General aviation
Make and model
Beech 1900D
Engine
Pwa PT6A67D
Part
Blower
Part number
1143800281
Condition
Failed
Location
Air Distribution
Stage of operation
NR
How discovered
V
Nature of condition
B
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) PILOT REPORTED SMOKE AND BAD SMELL IN CABIN. BLOWER (AFT) ASSY WAS REMOVED AND INSPECTED. INSP FOUND ARCING AT THE BRUSH COVER ATTACH SCREWS, AND ON BRUSH COVER WHERE 1 BRUSH LEAD WAS HUNG UP ON BRUSH HOLDER. THE LEAD WAS CLEARLY SQUASHED DOWN TO CLEAR COVER. THE COMMUTATOR HAS CLEARLY BEEN OVERHEATED, PROBABLY CAUSED BY THE HUNG BRUSH. THE LOW SPEED RESISTORS ARE BURNED UP WITH THE ASSOCIATED WIRING SHOWING SIGNS OF SIGNIFICANT HEAT. INSULATING WIRE SLEEVE HAS DARK HEAT RELATED STAINING AT EACH ADEL CLAMP. THE THERMAL PROTECTION DOES NOT APPEAR TO HAVE WORKED. IT APPEARS THAT MORE THEN ONE CONTRIBUTING FACTOR WAS RESPONSIBLE FOR FAILURE OF THE BLOWER ASSY. (TC20100204008)