What was found
(CAN) DURING A BI-WEEKLY INSP, AN AME NOTICED THAT THE RT INBD KRUEGER FLAP DID NOT SEEM TO BE DEPLOYED FULLY, AS COMPARED WITH THE OTHERS. ON INSP IT WAS NOTED THAT THE 3 BULLNOSE WAS DISCONNECTED AND THE HARDWARE WAS MISSING. THE AREA WAS INSPECTED FOR FURTHER DAMAGE AND IT WAS NOTED THAT A COTTER PIN WAS NOT INSTALLED IN THE RT OTRD POSITION. THE CORRECT HARDWARE WAS INSTALLED AND THE SYS WAS FUNCTION CHECKED SERVICEABLE. A REVIEW OF MX RECORDS SHOW THAT THE LAST TIME THAT AREA HAD MX CARRIED OUT WAS IN THE PRELEASE CHECKS. HAVE INITIATED A CHECK OF OTHER ACFT FOR THE SAME ISSUE, NONE FOUND INCORRECT AT THIS POINT. WILL UPDATE THIS SDR WHEN THE INSPECTIONS ARE COMPLETE. (TC 20100216012)