Service difficulty report · Regulator · Bombdr BD7001A10

Difficulty date
June 11, 2010
Submitted
January 4, 2011
Operation
Air carrier
Make and model
Bombdr BD7001A10
Aircraft time
18 hours
Engine
Rroyce BR700710A220
Part
Regulator
Part number
80637006
Condition
Defective
Location
Oxygen Bottle
Stage of operation
IN
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

4 CYLINDER ASSEMBLIES WERE RECEIVED FOR HYDROSTATIC TESTING. UPON REMOVAL OF REGULATORS FROM CYLINDERS, VISUAL INSP OF THE REGULATORS DETECTED DEFORMATION OF THE REGULATOR BODIES AT AND IN THE VICINITY OF THE THREADS USED TO SECURE THE REGULATORS TO THE CYLINDERS. 2 OF THE 4 REGULATORS ARE AFFECTED. MFG DATE OF THIS CYL ASSY IS 01-2009, MFG DATE MARKED ON THE REGULATOR IS 10-2008. THIS ASSY HAS BEEN SUBJECT TO 1 PREVIOUS HYDROSTATIC TEST SINCE MFG IN 08-2009. CASP SUSPECTS A MFG DEFECT, AND CONSIDERS THIS A POTENTIALLY LIFE THREATENING DEFECT/DISCREPANCY THAT COULD RESULT IN THE REGULATOR CATASTROPHICALLY SEPARATING FROM THE FULLY CHARGED (1850 PSI) CYLINDER DURING OPERATION, HANDLING OR SHIPPING. RECENTLY HAD A REGULATOR OF THE SAME TYPE FAIL IN THE SAME AREA WHEN REINSTALLING THE REGULATOR TO A CYLINDER. SUSPECTED THE REGULATOR WAS OVER TORQUED, SO NO FURTHER ACTION WAS TAKEN AT THE TIME. IN LIGHT OF THE MATERIAL DEFORMATION FOUND ON THESE 2 REGULATORS, OVER TORQUE SEEMS UNLIKELY AND THE POSSIBILITY OF A MFG DEFECT MUST BE CONSIDERED.