Service difficulty report · Slat System · Emb ERJ190100IGW

Difficulty date
August 23, 2010
Submitted
January 4, 2011
Operation
Air carrier
Make and model
Emb ERJ190100IGW
Aircraft time
6,323 hours
Engine
Ge CF3410E5A1
Part
Slat System
Condition
Failed
Stage of operation
CL
How discovered
O
Nature of condition
F
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AFTER DEPARTURE, THE FLIGHT CREW ENCOUNTERED A SLAT FAILURE AT 1000 FT AGL. THE SNAG WAS NOT RESOLVED, THEREFORE THE ACFT RETURNED TO POINT OF DEPARTURE. T/S IAW FIM 27-81-00-810-805-A, STEP 1, SF-ACE CLEAR INHIBITS PROCEDURE CARRIED OUT. RESET SUCCESSFUL. (TRANSITORY CONDITION OF SLAT/FLAP ACTUATOR CONTROL ELECTRONIC UNIT 1 AND 2), CONSIDER SERVICEABLE.