Service difficulty report · Fan · Cndair CL6002D24

Difficulty date
February 24, 2011
Submitted
September 14, 2015
Operation
General aviation
Make and model
Cndair CL6002D24
Part
Fan
Part number
GG67095028
Condition
Failed
Location
Lavatory
Part time
6,116 hours
Stage of operation
CL
How discovered
O
Nature of condition
B
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) "SMOKE" RIGHT AFTER T/O THE FWD LAV WARNING MESSAGE CAME ON. STARTED GOING THROUGH THE NON NORMAL PROCEDURES IAW THE POM AND THEN THE LIGHT WENT OUT. THERE WAS A STRONG UNNATURAL ODOR EMITTING FROM THE LAV IAW F/A. COULD ALSO DETECT ODOR IN COCKPIT. INSPECTED FWD GALLEY AND FWD LAV AREA FOR CAUSE OF SMOKE, NO DEFECTS NOTED. MDC SHOWS LAV FAN FAILED/WIRING, LOW FAN SPEED, FAN WAS REPLACED IAW AMM.