What was found
(CAN) DURING GEAR RETRACTION AFTER TAKEOFF, THE GEAR IN-TRANSIT LIGHT DID NOT EXTINGUISH AND THE NOSE GEAR WAS VISUALLY VERIFIED AS PARTIALLY IN THE UP POSITION. THE GEAR WAS EXTENDED NORMALLY IN THE DOWN AND LOCKED POSITION AS INDICATED BY THE GEAR LIGHTS AND THE ACFT LANDED NORMALLY. THE ACFT WAS BROUGHT INTO THE HANGAR, PLACED ON JACKS AND UPON INVESTIGATION EACH OF THE NOSE GEAR LOCK LINK ASSEMBLIES (2) WERE FOUND BROKEN INTO 2 PIECES. THESE LINKS ATTACH THE HYD ACTUATOR TO THE NOSE GEAR UPPER DRAG LINK ASSY, AND ARE DIFFICULT TO SEE AS THEY ARE LOCATED ON THE UPPER PORTION OF THE DRAG LINK.