What was found
(CAN) WHILE COMMENCING APPROACH, FLAPS 1 SELECTED AND SLATS LOCK MESSAGE APPEARED ON ECAM AT APPROX 8000 FT. MX TROUBLESHOOTING PERFORMED IAW TSM 27-81-00-810-815, WTB RESET SFCC NR 1 AND SFCC NR 2 SLATS LOCKED MESSAGE CLEARED. ALL LT AND RT SLAT ACTUATORS INSPECTED, NO TORQUE LIMITERS TRIPPED. TSM 27-81-00-810-815 COMPLETED. NO FAULTS.