Service difficulty report · Wire Harness · Emb ERJ190100IGW

Difficulty date
February 18, 2012
Submitted
September 14, 2015
Operation
General aviation
Make and model
Emb ERJ190100IGW
Aircraft time
12,686 hours
Engine
Ge CF3410E5A1
Part
Wire Harness
Condition
Failed
Location
Slat
Stage of operation
NR
How discovered
9
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) CREW HAD A SLAT FAILURE ON ARRIVAL. CREW CHECKED LANDING DISTANCE REQUIRED AND MADE NORMAL LANDING WITH FLAPS 2, NO EMERGENCY WAS DECLARED AS "FLAP 1" WAS SELECTED, WE RECEIVED A "SLAT FAIL" MESSAGE ON THE EICAS. "SHAKER ANTICIPATED" WAS ALSO LATER DISPLAYED ON THE EICAS. QRH PROCEDURE WAS COMPLETED. R & R RT WING OTBD SLAT HARNESSES IAW AMM 27-83-07 & PERFORMED SLAT CONTROL SYS OPS TEST IAW AMM 27-80-00-710-801, OPERATIONAL TEST GOOD.

More about the Emb ERJ 190-100 IGW