Service difficulty report · Connector · Cndair CL6002D24

Difficulty date
January 30, 2013
Submitted
September 14, 2015
Operation
General aviation
Make and model
Cndair CL6002D24
Part
Connector
Condition
Failed
Location
Overtemp Sys
Stage of operation
NR
How discovered
O
Nature of condition
N
Precautionary procedure
B

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) ANTI-ICE DUCT WARNING MESSAGE, WHILE ON DOWNWIND TO LANDING. SHORTLY AFTER, THE MESSAGE CHANGED TO, ANTI-ICE DUCT CAUTION MESSAGE AND THE ANTI-ICE PAGE SHOWED WING HEAT OFF. THE CREW REPORTED THAT THE ACFT WAS FLYING IN MODERATE TO SEVERE ICING CONDITIONS. THE CREW FOLLOWED THE QRH, PERFORMING A SYS RESET. AN EMERGENCY WAS DECLARED AND THE ACFT LANDED UNEVENTFULLY. MAINTENANCE FOUND HIGH RESISTANCE THROUGH LOOPS A AND B OF THE LT WING, AND R & R CONNECTORS. LOOP RESISTANCE WAS RE-CHECKED AND FOUND SATISFACTORY.