Service difficulty report · Module · Emb ERJ190100IGW

Difficulty date
June 30, 2013
Submitted
September 14, 2015
Operation
General aviation
Make and model
Emb ERJ190100IGW
Aircraft time
16,655 hours
Engine
Ge CF3410E5A1
Part
Module
Part number
70253651901
Condition
Failed
Location
Central Computer
Stage of operation
NR
How discovered
O
Nature of condition
O
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) EMERGENCY DECLARED WITH ATC ACCOUNT OF BRIEF FIRE INDICATION. NO SMOKE VISIBLE IN ACFT BUT CABIN TEMPERATURE INCREASING. GENERIC O/O NR 3 REPLACED IAW AMM 31-41-06. CARGO HI-RATE BOTTLE REPLACED IAW AMM 26-23-01. CARRIED OUT WIRING CHECK IAW WDM 26-23-50. FOUND HIGH RESISTANCE ON GROUND STUD GS0287, 336 OHMS. UPON INSPECTION FOUND GROUND STUD VERY LOOSE. TIGHTENED AND SECURED, RESISTANCE CHECK CONFIRMED GROUND GOOD. OPS TESTED IAW 26-23-01. CHECK SERV.