Service difficulty report · Selector Valve · Pilats PC1247

Difficulty date
April 5, 2014
Submitted
March 12, 2015
Operation
General aviation
Make and model
Pilats PC1247
Aircraft time
2,034 hours
Part
Selector Valve
Part number
9603001272
Condition
Failed
Location
Landing Gear
Part time
2,285 hours
Stage of operation
NR
How discovered
9
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) LANDING GEAR SELECTOR LEAKING INTERNALLY IN "DOWN" POSITION. CAUSES HYDRAULIC PUMP TO CYCLE EXCESSIVELY ON GROUND AFTER PROLONGED GROUND OPERATIONS. CAS "HYDRAULICS" ANNUNCIATOR TO ILLUMINATE REQUIRING GEAR SWING TO RESET.