Service difficulty report · Hose · Cndair CL6002D24

Difficulty date
April 8, 2014
Submitted
March 12, 2015
Operation
General aviation
Make and model
Cndair CL6002D24
Aircraft time
8,685 hours
Engine
Ge CF348C5
Part
Hose
Part number
AE71357812
Condition
Failed
Location
Mlg
Part time
7,797 hours
Stage of operation
LD
How discovered
O
Nature of condition
K
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) AFTER LANDING AND DURING A 180 DEGREE TURN AT RUNWAY END FOR BACK TRACK TO EXITING TAXIWAY, FLIGHT CREW RECEIVED A NR 3 HYDRALIC SYS LOW PRESSURE CAUTION MESSAGE, NR 3 HYDRALIC FLUID QTY WAS OBSERVED AT 0 PERCENT. FLIGHT CREW SHUTDOWN NR 3 HYD SYS AND TAXIED TO GATE POSTION. AFTER PASSENGER OFF LOADING, THE FLIGHT CREW OBSERVED HYD FLUID IN THE AREA OF THE NLG BAY AND AFT ALONG THE LOWER FUSELAGE. MAINTENANCE WAS DISPATCHED TO THE ACFT AND DISCOVERED THE NLG RETRACT ACTUATOR HOSE ASSY WAS SPLIT OPEN WHERE THE HOSE IS SWAGED INTO THE FITTING END.