What was found
(CAN) DUE TO DISCLOSURE OF A POSSIBLE AGB LINE 6 GEAR MANUFACTURING PROBLEM, A SPECIAL REDUCED INTERVAL MCD INSPECTION PROGRAM WAS BEGUN FOR THIS ENGINE. AT THE FIRST MCD INSPECTION A SMALL AMOUNT OF MAGNETIC MATERIAL WAS FOUND ON THE AGB/TGB DETECTOR. THE MATERIAL WAS SENT TO THE LAB FOR ANALYSIS AND IT WAS CONFIRMED TO BE AMS 9310 OR 9315. AN INQUIRY WAS SUBMITTED TO MFG AND SERVICE REQUEST 7-1-4768887202 ADVISED REPLACING THE AGB WITHIN 25 CYCLES. THIS IS TENTATIVELY PLANNED FOR OCT 27TH.