What was found

(CAN) LANDING GEAR WOULD NOT RETRACT AFTER TAKE OFF, RETURNED. DECLARED EMERGENCY. FOUND ACTIVE MESSAGE (NLG WOFW 2 SNSE/WRG FAULT. FAULT CODE 32612303PSS. CARRIED OUT T/SING AS PER FIM 32-61-00-810-891-A.. RESET BREAKER MAU 3 PWR 1.RHCBP (DC ESS BUS 2) TRANSITORY CONDITION OF THE PROXIMITY SENSOR ELECTRONIC MODULE 2. FAULT MESSAGE CLEARED. CLEANED CORROSION AS PER STANDARD PRACTICES. RE-INSTALLED CANON PLUG AND TESTED SENSOR POSITION THROUGH CMC PSEM TEST. TESTED SERVICABLE.