Service difficulty report · Receptacle · Emb ERJ190100IGW

Difficulty date
February 7, 2015
Submitted
March 12, 2015
Operation
General aviation
Make and model
Emb ERJ190100IGW
Aircraft time
21,772 hours
Part
Receptacle
Part number
17015144401
Condition
Defective
Location
External Power
Stage of operation
TX
How discovered
O
Nature of condition
B
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) WHEN THE RAMP CONNECTED THE GPU, SPARKS APPEARED ON THE ACFT & NOTICED BRANDING FROM THE SPARKS ALONG WITH BURNING SMELL. GPU WAS DISCONNECTED IMMEDIATELY. MTC WAS ADVISED. EXTERNAL AC GND POWER RECEPTACLE REPLACED IAW AMM 24-42-03, FUNCTIONED IAW AMM 24-42-00-710-801-A.