Service difficulty report · Fan · Airbus A321211

Difficulty date
April 8, 2015
Submitted
August 5, 2015
Operation
General aviation
Make and model
Airbus A321211
Aircraft time
44,539 hours
Engine
Cfmint CFM565B3P
Part
Fan
Part number
EVT3454H
Condition
Failed
Stage of operation
DE
How discovered
O
Nature of condition
B
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) CREW REPORTED A BURNING PLASTIC ODOR ON DESCENT. IFS & PILOTS WENT TO HOSPITAL & CLINIC TO SEEK MEDICAL TREATMENT. ACFT WAS CHECKED BY MTC & THEY CONCUR THERE IS A ODOR. REPLACED AVIONICS COOLING EXTRACT FAN IAW AMM 21-26-51 PB 401 & BOTH RECIRCULATION FANS IAW AMM 21-21-51 PB 401. TESTED SERVICEABLE.