Service difficulty report · Ecu · Bombdr CL6002D15

Difficulty date
April 17, 2015
Submitted
August 5, 2015
Operation
General aviation
Make and model
Bombdr CL6002D15
Aircraft time
29,172 hours
Engine
Ge CF348C5
Part
Ecu
Part number
766389R
Condition
Overheated
Location
Slat System
Stage of operation
NR
How discovered
O
Nature of condition
B
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) MX NOTICED AN ELECTRICAL ODOR IN AREA OF MAIN CABIN DOOR. FOUND ODOR TO BE COMING FROM E & E BAY. WHILE LOOKING FOR THE SOURCE OF SMELL, DROPPED POWER OFF OF THE ACFT & NOTICED CB CBP2-R1, FLAPS CONT CH 1, CB WAS POPPED. WITH POWER ON, ACFT COULD NOT RESET CB. WHEN SFECU 1 WAS PULLED FROM ACFT, NOTICED DARK BURNED AREA ON BACK TOP PORTION OF BOX. THERE MAY HAVE BEEN A FLAME AS THE WATER DRIP TRAY ON TOP OF THE SFECU WAS SLIGHTLY WARPED BY FLAME OR HEAT & ALSO HAD A LOT OF SOOT ON IT ALSO. NR 1 SFECU CB WILL NOT RESET. FOUND NR 1 SFECU TO BE AT FAULT FOR ELECTRICAL ODOR & CIRCUIT BREAKER TRIPPING. REPLACED NR 1 SFECU & FLAPS SLATS FUNCTION TESTED SERVICEABLE.