Service difficulty report · Controller · Emb ERJ190100IGW

Difficulty date
June 23, 2015
Submitted
August 5, 2015
Operation
General aviation
Make and model
Emb ERJ190100IGW
Aircraft time
24,555 hours
Engine
Ge CF3410E5A1
Part
Controller
Part number
SYLZ53118
Condition
Failed
Location
Window Heat
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) AFTER TAKEOFF CREW REPORTED A WINDSHIELD HEAT FAILURE. DUE TO CONVECTIVE ACTIVITY EN ROUTE & FORECAST THE FLIGHT IS RETURNING. LANDING WEIGHT WILL BE BELOW MAXIMUM. RESOLUTION IAW FAULT CODE 30420030AI1, WINDSHIELD HEATER CONTROL REPLACED IAW AMM 30-42-01 PB 401. POWER APPLIED MORE THAN 1/2 HR, NO EICAS MSG. OPERATIONS CHECKED SERVICEABLE.