Service difficulty report · Wire · Braero HS7482A

Difficulty date
October 2, 2015
Submitted
April 22, 2016
Operation
General aviation
Make and model
Braero HS7482A
Aircraft time
41,929 hours
Engine
Rroyce DART5342
Part
Wire
Condition
Chafed
Location
Fire Detection
Stage of operation
CR
How discovered
O
Nature of condition
N
Precautionary procedure
E, A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) AIRCRAFT DECLARED AN EMERGENCY AFTER SHUTTING DOWN NR 1 ENGINE IN FLIGHT AFTER ENGINE FIRE WARNING LIGHT. CREW BLEW THE 2 FIRE EXTINGUISHER BOTTLES, BUT LIGHT REMAIN ON. THE PLANE LAND SAFELY. MAINTENANCE FOUND FIRE WIRE P/N D1384N TO BE THE FAULT. THEY INSPECT THE REST OF THE SYSTEM AND THEY ALSO FOUND FIRE WIRE P/N D890N SHAFFING. BOTH FIRE WIRES HAVE BEEN REPLACED.