Service difficulty report · Generator · Bombdr DHC8402

Difficulty date
November 27, 2015
Submitted
April 22, 2016
Operation
General aviation
Make and model
Bombdr DHC8402
Engine
Pwc PW150A
Part
Generator
Condition
Failed
Location
Ac System
Stage of operation
AP
How discovered
O
Nature of condition
G
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) JUST HAD A DOUBLE AC GENERATOR FAILURE ON APPROACH. THE NR 1 EVENTUALLY RESET BUT FAILED AGAIN PRIOR TO LANDING. THE NR 2 AC GENERATOR WOULD NOT RESET. ACFT LANDED WITHOUT AC POWER IN ICING CONDITIONS. ENGINEERS HAVE SINCE GROUND RUN THE AIRCRAFT AND FUNCTIONED THE AC SYSTEM WITH ALL HEATERS ON AND PROP DE-ICING AND ARE UNABLE TO FAULT THE AC SYSTEM. THE ENGINEERS WILL INSPECT BOTH PROPELLER BACK PLATES FOR THE BUS BAR CONDITION AND ALSO DROP THE FLAPS AND HAVE A LOOK AT THE WIRING ON THE REAR SPAR ON SATURDAY IT HAD A NR 2 PROP DE-ICE CAUTION AND ONE DE-ICE HARNESS WAS BADLY DAMAGED, PROBABLY HAD CAUGHT IN THE SPINNER AT SOME TIME. HARNESS WAS REPLACED. (TMCU WAS OK) SUSPECT A PROP HARNESS HAD AN INTERMITTENT SHORT WHICH MAY HAVE CAUSED THE DUAL AC GEN FAILURE.