What was found
(CAN) REPORT LT MLG DOOR INDICATION PROBLEM. DOORS STAYS OPEN AFTER LANDING GEAR EXTENSION CYCLE. A/C LANDED WITH GRAVITY EXTENDED GEAR WITHOUT FURTHER PROBLEMS. AFTER PERFORMING T/S LST ENGINEER FOUND STORED FAULT `LGDLK 2 PROX SENSOR OPEN`, IAW WM 32-61-00-1B LOCATED CONNECTOR 3261-J24. AFTER DISASSEMBLY FOUND RECEPTACLE J24 DAMAGED BY CORROSION. DUE TO THIS CONDITION TWO WIRES IN CONNECTOR WERE NOT CONNECTED TO THEIR CONTACTS. CONNECTOR 3261-J24 WITH SOCKETS REPLACED, IAW WM 20-17-23. AIRCRAFT HAS BEEN RELEASED TO SERVICE. (TC NR 20180116015).