Service difficulty report · Floor Support · Cndair CL6002B19

Difficulty date
March 27, 2019
Submitted
August 17, 2020
Operation
General aviation
Make and model
Cndair CL6002B19
Part
Floor Support
Part number
601R31133
Condition
Corroded
Location
Cabin
Part time
29,149 hours
Stage of operation
IN
How discovered
9
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) OPERATOR REPORTED (6) BLENDED CORROSION AREAS ON THE FLOOR SILL (DWG: 601R31133, 0.063 NOMINAL THICKNESS, REF) BETWEEN FS559.00+L6 AND FS559.00+48, RHS. DIMENSIONS ARE: ITEM #1: 6.0 L X 1.5 W X REMAININIG THICKNESS 0.062 ITEM #2: 4.0` L X 1.5 W X REMAININIG THICKNESS 0.042 ITEM #3: 2.0 L X I.0 W X REMAININIG THICKNESS 0.058 ITEM #4: 2.5 L X I.0 W X REMAININIG THICKNESS 0.047 ITEM #5: I.6 L X 1.0 W X REMAININIG THICKNESS 0.050 ITEM #6: 1.4 L X 0.9 W X REMAININIG THICKNESS 0.060 OPERATOR REPORTED (3) BLENDED CORROSION AREAS ON THE RH FLOOR SILL INTERCOSTAL M/C STA 559 - 559+16, E.C.S. OPTION (DWG: 601R38842, REF) WITH A MINIMUM OF REMAININIG THICKNESS 0.016 . NOTE: THE RH FLOOR SILL INTERCOSTAL M/C STA 559 - 559+L6, E.C.S. OPTION (DWG: 60LR38842, REF) WILL BE REPLACED.