What was found
(CAN) OPERATOR REPORTED (6) BLENDED CORROSION AREAS ON THE FLOOR SILL (DWG: 601R31133, 0.063 NOMINAL THICKNESS, REF) BETWEEN FS559.00+L6 AND FS559.00+48, RHS. DIMENSIONS ARE: ITEM #1: 6.0 L X 1.5 W X REMAININIG THICKNESS 0.062 ITEM #2: 4.0` L X 1.5 W X REMAININIG THICKNESS 0.042 ITEM #3: 2.0 L X I.0 W X REMAININIG THICKNESS 0.058 ITEM #4: 2.5 L X I.0 W X REMAININIG THICKNESS 0.047 ITEM #5: I.6 L X 1.0 W X REMAININIG THICKNESS 0.050 ITEM #6: 1.4 L X 0.9 W X REMAININIG THICKNESS 0.060 OPERATOR REPORTED (3) BLENDED CORROSION AREAS ON THE RH FLOOR SILL INTERCOSTAL M/C STA 559 - 559+16, E.C.S. OPTION (DWG: 601R38842, REF) WITH A MINIMUM OF REMAININIG THICKNESS 0.016 . NOTE: THE RH FLOOR SILL INTERCOSTAL M/C STA 559 - 559+L6, E.C.S. OPTION (DWG: 60LR38842, REF) WILL BE REPLACED.