Service difficulty report · Relay · Bombdr DHC8400

Difficulty date
July 20, 2019
Submitted
August 17, 2020
Operation
General aviation
Make and model
Bombdr DHC8400
Aircraft time
6,901 hours
Part
Relay
Part number
MS24166D1
Condition
Faulty
Location
Anti-Ice Sys
Stage of operation
CR
How discovered
9
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) REPEATED STANDBY PITOT HEAT CAUTION IN FLIGHT, PITOT TUBE AND TMU WERE REPLACED BUT THE DEFECT RETURNED, MTC`S TROUBLESHOOTING INDICATE THAT TAPPING THE RELAY RECTIFIED THE FAULT. THE RELAY WERE PREVIOUSLY REPLACED 9 DAYS AGO. THE 3000-K5 RELAY WERE REPLACED AND THE STANDBY PITOT HEAT WERE TESTED WITH NO FURTHER FAULT NOTED. NO REPEATED FAULT NOTED TO DATE. (TC# 20190722013)