What was found
(CAN)AIRCRAFT LANDING GEAR FAILED TO OPERATE DUE TO A RUPTURED HYDRAULIC LINE. OPERATING PRESSURE OF HOSE IS 1100 PSI. SUBMITTER SUSPECTS THAT THE HOSE MAY HAVE BEEN WEAKENED BY SALT WATER EXPOSURE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
(CAN)AIRCRAFT LANDING GEAR FAILED TO OPERATE DUE TO A RUPTURED HYDRAULIC LINE. OPERATING PRESSURE OF HOSE IS 1100 PSI. SUBMITTER SUSPECTS THAT THE HOSE MAY HAVE BEEN WEAKENED BY SALT WATER EXPOSURE.