(CAN)LANDING GEAR SELECTED UP ON CLIMB DEPARTURE, ECAM MESSAGE WARNING INDICATED NOSE GEAR NOT UPLOCKED, NOSE LDG REMAINED EXTENDED. LANDING GEAR SELECTED DOWN, BOTH MAIN LANDING GEAR REMAINED RETRACTED. L ANDING GEAR THEN SELECTED UP AND NORMAL OPERATION OCCURRED. THE FOLLOWING MAINTENANCE ACTION TOOK PLACE, NOSE LANDING GEAR SENSORS INSPECTED SATISFACTORILY, TARGETS (GAPS) CHECKED: 24GA ADJUSTED AND TARGETS 36GA AND 38GA FOUND LOOSE AND WERE SECURED.