Service difficulty report · Reducing Valve · Emb EMB110P1

Difficulty date
December 30, 1996
Submitted
March 26, 2000
Operation
General aviation
Make and model
Emb EMB110P1
Part
Reducing Valve
Condition
Out Of Adjust
Location
Mlg
Stage of operation
CL
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) ON TAKEOFF LANDING GEAR SELECTED TO RETRACT. RED IN TRANSIT LIGHT WOULD NOT GO OUT. GEAR LEVER TO EXTEND AND THREE GREEN INDICATED. PRESSURE REDUCING VALVE FOUND TO BE LOW AT 1300 PSI. VALVE ADJUSTED TO 1400+/-50 PSI.