Service difficulty report · Uplock · Swrngn SA226TC

Difficulty date
August 20, 1998
Submitted
March 26, 2000
Operation
Air carrier
Make and model
Swrngn SA226TC
Engine
Garrtt TPE33110UA
Part
Uplock
Part number
275100059
Condition
Failed
Location
Lt Mlg
Stage of operation
AP
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) ON APPROACH, LEFT GEAR DID NOT EXTEND WHEN GEAR SELECTED. NO IN-TRANSIT LIGHT NOTED, INDICATING GEAR DID NOT RELEASE FROM UPLOCK. EMERG EXTENSION CARRIED OUT BUT LEFT GEAR STILL FAILED TO EXTEND. GEAR RETRACTED AND NORMAL EXTENSION CARRIED OUT. LEFT STILL FAILED. ONCE AGAIN EMERG TRIED AND AFTER SEVERAL PUMPS WITH EMERG PUMP, IT RELEASED. A/C LANDED OK. SUBSEQUENT CHECKS CONFIRMED THAT SYSTEM WOULD NOT RELEASE DURING NORMAL GEAR EXTENSION. INSP FOUND THAT UPLOCK LATCH RELEASE MECHANISM HAD EXCESSIVE PLAY FROM ELONGATED HOLES IN TUBE, P/N 27-51000-59, WHERE ARMS AND STOPS ARE SECURED TO IT. THIS EXCESSIVE PLAY PREVENTED UPLOCK RELEASE MECHANISM FROM HAVING SUFFICIENT TRAVEL TO RELEASE UPLOCK LATCH