What was found
INSPECTION FOUND FORWARD CARGO DOOR JAMB DENTED AT STA 440 AT FLOOR LINE. THE DENTED AREA WAS REMOVED AND A REPAIR WAS INSTALLED IAW DRAWING 69-15224 AND SRM 51-70-13.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND FORWARD CARGO DOOR JAMB DENTED AT STA 440 AT FLOOR LINE. THE DENTED AREA WAS REMOVED AND A REPAIR WAS INSTALLED IAW DRAWING 69-15224 AND SRM 51-70-13.