What was found
INSPECTION FOUND STRINGER 28R AND 29L CORRODED AT STA 323 AT FORWARD SIDE OF E&E DOOR JAMB. THE STRINGER SECTIONS WERE REMOVED AND REPLACED IAW SRM 51-10-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND STRINGER 28R AND 29L CORRODED AT STA 323 AT FORWARD SIDE OF E&E DOOR JAMB. THE STRINGER SECTIONS WERE REMOVED AND REPLACED IAW SRM 51-10-2.