What was found
INSPECTION FOUND A .5 INCH CRACK AND UPPER SHIM DAMAGE IN FLOOR PANEL SUPPORT AT STA 540, LBL 10. THE FLOOR SUPPORT WAS REMOVED AND REPLACED IAW SRM 51-10-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND A .5 INCH CRACK AND UPPER SHIM DAMAGE IN FLOOR PANEL SUPPORT AT STA 540, LBL 10. THE FLOOR SUPPORT WAS REMOVED AND REPLACED IAW SRM 51-10-02.