What was found
INSPECTION FOUND FLOORBEAM CORRODED AT STA 325, LBL 48 - RBL 45. THE FLOORBEAM WAS REPAIRED IAW SRM 53-00-51, FIGURE 201.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND FLOORBEAM CORRODED AT STA 325, LBL 48 - RBL 45. THE FLOORBEAM WAS REPAIRED IAW SRM 53-00-51, FIGURE 201.