What was found
A FLIGHT ATTENDANT REPORTED SMOKE AND FUMES IN THE CABIN IN THE VICINITY OF ROWS 24-28 DURING CLIMBOUT. THE SMOKE WAS ACCOMPANIED BY RECIR FAN STATUS MESSAGE DISPLAYED. THE SMOKE/FUMES/FIRE/ ELECTRICAL CHECKLIST WAS PERFORMED, THE RECIRCULATION FANS WERE TURNED OFF AND THE SMOKE CEASED. THE FLIGHT WAS CONTINUED AND LANDED SAFELY AT ITS SCHEDULED STATION WITHOUT FURTHER INCIDENT. MAINTENANCE FOUND THE AFT UPPER RECIRCULATION FAN AT FAULT. THE FAN WAS REMOVED AND REPLACED IAW MM 21-25-01. OPERATIONAL CHECKS WERE GOOD WITH NO OTHER DEFECTS NOTED.