What was found
RT WING RT MLG O/B STAB LWR I/B HOLE AT SECOND OVERSIZE OF.3432 -.3442 & STILL HAS INDICATION. REPAIRED PER ECRA 5740-02276. INITIATED DIP #57-DIP CONTROL #07 526 READS: ACCOMPLISH PERMANENT REPAIR BEFORE 18-OCT-2011 PER ECRA 5740-02276 PART 3. PLANNING TO CONTACT ENGINEERING AFTER 1 8-AUG-2011 BUT BEFORE 18-SEP-2011 FOR REPAIR INSTRUCTIONS. ACCOMPLISH A PERMANENT REPAIR BEFORE 18-OCT-2011 PER ECRA 5740-02276 PERT 3. PLANNING IS TO CONTACT ENGINEERING AFTER 18-AUG-2011 BUT BEFORE 18-SEP-2011 FOR REPAIR INSTRUCTIONS DIP C/N 07526 ISSUED NOTE: THIS ECRA IS BEING EVALUATED FOR DAMAGE TOLERANCE UNDER 14 CFR 25.571.