As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CABIN STA 325 RBL 38 TO 41 FLOORBEAM SPLICE PLATE CORRODED. STA 325 RBL 38 TO 41 FLOORBEAM SPLICE PLATE CORROSION BLEND OUT D:0.019" (ORG.063") OUT OF SRM 53-00-51 ALLOWABLE DMG 1 FIG 101 LIMIT AND SPLICE PLATE REPAIRED AS PER SRM 53-00-51 REPAIR 1 FIG 201 WORKING DETAIL REFER NRC 200-11025306784) AT STA 325 RBL 37 TO LBL 63.