DENT FUSELAGE SKIN STA 1706 BETWEEN STR 5 RT AND STR 6 RT APPROX INSTALLED REPAIR DOUBLER REF SRM 53-00-01 REPAIR 3 FIG 201 PG 207 TABLE 5 CATEGORY B REPAIR REQUIREMENTS 37500 FLT CYCLES PER NOTE J LFEC PER NOTE E. ADDITIONAL INFORMATION REPAIR DOUBLER THICKNESS IS .071 2024T3 FOUND DENT IN FUSELAGE SKIN STA 1706, STR 5 RT TO STR 6 RT PER SRM 53-00-01, REPAIR 3, PG 207 INSTALLED REPAIR. PERFORM LFEC INSP AT 37,500 AFTER REPAIR WAS INSTALLED, THEREAFTER EVERY 3,000 FLT CYC'S.